iSA-621 & iSA-623 Ultra-High-Sensitivity Smart Vibration Meter
- 24-bit ADC with SNR >102 dB and ultra-wide dynamic range
- Bandwidth: iSA-621 0.1 Hz–1 kHz; iSA-623 0.1 Hz–200 Hz for ultra-low-frequency measurement
- iSA-621I uses an internal sensor; E has one external input; A supports internal and external sensors. iSA-623 has three external inputs
- Distributed synchronous measurement with Beidou timing accuracy of 1 μs
- High-speed Wi-Fi; 4G on iSA-621 G versions; optional built-in 4G on iSA-623
- 32 GB storage supporting over 100,000 measurement records
- All-aluminium housing, IP65 protection, 100 g shock resistance
- Scheduled operation for up to 1 week of unattended use; mobile app control
Need selection advice or an on-site demo? Use the buttons above and our engineers will reach out shortly.
Specifications
| Item | iSA-621I | iSA-621E | iSA-621A | iSA-623 | Note |
|---|---|---|---|---|---|
| Measurement Performance | |||||
| Channels | 1 | 1 | 1 | 1 channel | |
| Max Sample Rate | 20 kSps | 20 kSps | 20 kSps | Up to 20 ksps/ch | |
| Sample Rate Settings | 2 | 2 | 2 | — | |
| Range | ±0.5 g | ±0.5 g | ±0.5 g | ±0.5g | |
| ADC Resolution | 24bit | ||||
| Analog Performance | |||||
| Accuracy (FS) | National Class A | National Class A | National Class A | — | |
| Bandwidth | 0.1Hz–1K Hz | 0.1Hz–1K Hz | 0.1Hz–1KHz | 0.1Hz~200Hz | |
| Measurement Method | |||||
| Velocity Measurement | Calculated | Calculated | Calculated | — | |
| Acceleration Measurement | Direct measurement | Direct measurement | Direct measurement | — | |
| Sensor Configuration | |||||
| Internal Sensor | Yes | No | Yes | — | |
| External Sensor | No | Yes | Yes | — | |
| ICP | Yes | Yes | Yes | — | |
| Capture & Storage | |||||
| Capture Duration per Channel | >10 s | >10 s | >10 s | — | |
| Storage Capacity | 32 GB | 32 GB | 32 GB | 32 GB, over 100,000 measurement records | |
| Internal Trigger | Window trigger | Window trigger | Window trigger | — | |
| Trigger & Communication Interfaces | |||||
| Standard External Trigger | Yes | Yes | Yes | — | |
| Break-screen External Trigger | No | No | No | — | |
| Wi-Fi | Yes | Yes | Yes | 802.11 b/g/n | |
| 4G | No | No | No | SIM card slot, full-network support | |
| BeiDou | Yes | Yes | Yes | — | |
| USB | No | No | No | — | |
| Ethernet | No | No | No | — | |
| Mechanical, Power & Environment | |||||
| Dimensions | 80 mm×80 mm×80 mm | 80 mm×80 mm×80 mm | 80 mm×80 mm×80 mm | 8cm×8cm×8cm | |
| Power Supply | External DC 12 V | External DC 12 V | External DC 12 V | — | |
| Battery Life | 16 hours | 16 hours | 16 hours | 16 hours (continuous operation) | |
| Operating Temperature | -20 °C–60 °C | -20 °C–60 °C | -20 °C–60 °C | -30℃~60℃ | |
| Ingress Protection | IP65 | ||||
| Weight | 810 g | ||||
| Synchronisation & Sensor Input | |||||
| Multi-unit Sync Accuracy | 1 μs (BeiDou timing) | 1 μs (BeiDou timing) | 1 μs (BeiDou timing) | 1 μs with satellite timing | |
| Reliability | |||||
| Shock Resistance | 100 g | 100 g | 100 g | 100g | |
| Scheduled Operation | Approximately 1 week | Approximately 1 week | Approximately 1 week | — | |
| iSA-623 Additional Specifications | |||||
| Sensitivity | — | — | — | 10V/g | |
| External Channels | — | — | — | 3 channels | Compatible with IEPE sensors and geophones |
| Trigger Mode | — | — | — | Internal, external, manual, forced, and satellite-timed trigger | |
Related scenarios
Downloads
FAQ
- How do I choose an iSA-621 I, E or A model?
- I uses an internal sensor, E uses an external sensor, and A supports both. All three have 1 channel, 24-bit resolution, up to 20 kSps and 0.1 Hz–1 kHz bandwidth; choose a G version for 4G. iSA-623 provides 3 external sensor inputs and 0.1–200 Hz internal-channel bandwidth.